Fire Prevention Coating, "Flame Control"

"Flame Control" is a highly reliable product developed by collaborating with Flame Control Coatings Inc. the largest fire prevention paint manufacturer in the U.S.
There are two types of flame control, the bubble type and the reaction type.
The General bubble type swells its film up to 100 times when it touches the flame or high temperature, and it forms the heat resistant insulation and delays the extention of heat and flame through materials.
The reaction type contains ingredients that have fire extinguishing functions, and it delays the extention of heat and the flame by producing gas when it touches the flame or high temperature.
There are versions for w
ood, metal, concrete, and cable. Please choose one to meet your application.


For Wood [Indoor Use]

 

Solvent Base

 Flame Control 6 sealer
  ◆Wood Sealer/Clear
   (Prevents the paint film from whitening, which is caused by the moisture from wood.)
 Flame Control 166 [Primer]
  ◆Bubble type / Semi Gloss / Clear
 Flame Control 167 [Top Coat]
  ◆Reaction type / Gloss / Clear

Water Base

 Flame Control 20-20
  ◆Bubble type / Mat / White

For Metal [Indoor Use]

 Flame Control 173
  ◆Solvent based / Bubble type / Mat / White
  ◆Applicable materials : Aluminum, Aluminum alloy, Steel

For Concrete [Indoor Use]

 Flame Control 40-40
  ◆Water based / Reaction type / Mat / White
  ◆Applicable materials : Noncombustible materials
                  (Concrete, gypsum, nonflammable board etc.)

 Specification

 Flame Control 6 sealer +166+167(For wood)

1.Surface

Treatment

2. Sealer

Mixture

3. Sealer Painting

4.The Interval

Time for Primer

5.Primer Agitation
Remove wax and stains on the surface of wood and dry the surface. Dilution/Stirring brush
roller
spray
Air dry for 24 hours or more Dilution/Stirring
6.Primer

7.The Interval

Time of Top coat

8.Top Coat

Mixture

9.Top Coat Painting 10.Drying
brush
roller
spray
Air dry for 48 hours or more Dilution/Stirring brush
roller
spray
Air dry for 48 hours or more
[*1]

[*1] Air temperatures affect the drying time.
[*Notice] Painting Conditions:Please abstain from painting under the condition below.
・When rainfall and snow are forecasted.

・When the outside temperature is under 5°C, and the difference with the dew point is within 3°C.

・When the relative humidity is 85% or more.

・When it is windy.

 

 Certificate of Frame Control

Flame Control 6 sealer + Flame Control 166+ Flame Control 167
Flame Control 20-20
Flame Control 40-40

・UL tunnel test : Evaluation class A
This test is generaly called "Stinar Tunnel Test". It is a test to see how the flame moves, the amount of smoke it generates, and the level of self burning by using a 50.8cmx762cm board.
The standard is that the combustion condition of asbestos cement board suppose 0, and the combustion condition of non-coated oak tree suppose 100, then the effectiveness was shown by the numerical value. The enhancing index of the flame is evaluated in the damage classification of the United States as follows.
Evaluation class A:0 -25, Evaluation class B:26 - 75, Evaluation class C:76 - 100
*UL tunnel test : The safety standard in the United States with authorities most(The content of the test is based on the ASTM-E-84.)
ASTM-E-84 : The surface combustion material standard of construction enacted by the America Society of Testing Materials.

 

 

 Fire Test

 1 minute lapses after the igniting.

Bare wood.

[ Frame Control 166 ]

is painted.

[ Frame Control 20-20 ]

is painted.

 

 

 